Current Issue : April-June Volume : 2023 Issue Number : 2 Articles : 5 Articles
Solar energy harvesting devices are widely used in smart agriculture nowadays. However, when lighting conditions are weak, such as through the night or on cloudy days, efficiency decays a lot. Additionally, as time goes by, more and more dust and bird droppings accumulate on the panel, which decreases the performance significantly. This paper aims to overcome the disadvantages mentioned above, and a novel wind–solar hybrid energy harvesting approach is proposed with an oscillation-induced dust-cleaning function. A wind-induced vibration device is specially designed in order to generate electrical energy and/or clean the photovoltaic panel. While in good lighting conditions, the device could keep the panel in a stable state and optimize the photovoltaic power generation efficiency. Such a hybrid energy harvesting approach is called a “suppress vibration and fill vacancy” algorithm. The experimental platform of the proposed device is introduced, and both experimental and simulation results are attained, which prove that using this device, we could realize multiple purposes at the same time....
This paper proposes a multisource power plant management strategy for the proposed structure. This power plant consists of photovoltaic, wind, and grid. The principle of this management strategy is based on the reference currents and defines two components of the current namely a harmonic component related to the harmonics contained in the load current and current called fundamental related to the fundamental of the load current. This proposed strategy allows the different renewable sources to supply the load partially or totally. The harmonic component performs the power quality function while the fundamental component feeds the load and injects the surplus production into the grid. The power management is done according to the established scenarios and responds to the demand of the load. The simulations were carried out with Matlab software, and these results show the performance of this strategy for this structure studied to fulfill the following functions: power supply to the load, power factor (PF) correction, harmonic elimination, reactive energy compensation, and injection in the network of a current with a low rate of harmonic distortion lower than 1% in accordance with the IEEE Std 519-2014 standard....
Reliable overhead transmission lines have a vital role in maintaining the reliability of power systems at a desirable level and ensuring the continuity of electrical energy. In this regard, a proper preventive maintenance program can ensure the reliable functioning of transmission lines. Based on the concept of reliability-centered maintenance, this paper proposes a preventive maintenance strategy that can be implemented in real power systems due to the limited data requirements. The priority of each line for preventive maintenance was obtained by two indices revealing the technical condition and importance of each line in the network. The proposed method was applied to a real transmission network in Khorasan province of Iran. In order to extract the condition index of lines, failure statistics during six recent years as well as technical data of lines were investigated. Moreover, this paper presents a two-stage method to determine the importance index of each line by evaluating the consequences of line failures on the network. The presented results show the efficiency of the proposed approach....
Driven by the carbon peaking and carbon neutrality target, the large-scale grid-connected of renewable energy such as wind and solar has increased, and the volatility and randomness have posed new challenges to the stability of the power grid frequency. In this case, battery energy storage is a grid auxiliary resource with fast response and adjustable parameters, which can provide frequency support for the grid system in a short period. This paper studies the frequency regulation strategy of large-scale battery energy storage in the power grid system from the perspectives of battery energy storage, battery energy storage station, and battery energy storage system, respectively. First of all, the droop control based on logistic function and the virtual inertia control based on piecewise function are proposed for battery energy storage frequency regulation, which improves the performance of battery energy storage power output effectively. Second, the weighting factor is set according to the current battery charge to achieve the most optimal distribution of frequency regulation power for each battery pack in the battery energy storage station. In the end, a control framework for large-scale battery energy storage systems jointly with thermal power units to participate in system frequency regulation is constructed, and the proposed frequency regulation strategy is studied and analyzed in the EPRI-36 node model. The results of the study show that the proposed battery frequency regulation control strategies can quickly respond to system frequency changes at the beginning of grid system frequency fluctuations, which improves the stability of the new power system frequency including battery energy storage. In addition, this paper also provides a certain reference for the construction of the new power system dispatching that integrates “Generation-Grid-Load-Storage” in the future....
To realize the economical consumption of wind energy (WE), an optimal dispatch strategy for wind-thermal-energy storage systems (WTESSs) is proposed. The scheduling model is divided into two stages. In the first stage, the strategy aims to shave peaks and fill valleys in the load curve using a time-of-use (TOU) electricity price and to reduce the variance of the net load and use the energy time-shift characteristics of energy storage systems (ESSs) to optimize their charging and discharging power. In the second stage, the strategy minimizes the cost of WTESSs, obtaining the output power of the thermal power units (TPUs) in each period. Considering the actual need for carbon reduction, a method for calculating the TPUs’ life loss cost under different variable load amplitudes is introduced, and a thermal power peaking cost model considering the ladder-type carbon trading model is constructed to calculate the cost accurately. In addition, to account for the fact that connecting all wind power outputs to the grid will significantly increase the grid peak regulation pressure and operational risk, a mathematical model for WE utilization is established to find the optimal power value for wind power grid connection in each period, which enables economical and practical WE scheduling. According to the simulation results, the overall peak-shaving cost of the system can be reduced by up to 23.95%, and the thermal power deep peak regulation cost can be reduced by up to 90.06%....